Energy UNITS FOR LIFT TABLE 1
Basic Description
This energy unit is made exclusively for that tiny lift table,Consisting of high pressure gear pump, AC motor, multi-functional manifold, valves, tank, and so forth. This energy unit has become extensively employed from the field of logistic units for example minifork lift, scissors lift and ariel operating platforms. The lower-ing movement is managed by the solenoid valve using the velocity controlled through the adjustable needle valve.
Power UNITS FOR LIFT TABLE two
Standard Description
This energy unit is made exclusively for that medium lift table, Consisting of remarkably effecient gear pump, AC motor, multifunctional manifold, valves, tank, ect. The lowering motion is actived by the solenoid valve and also the speed controlled through the adjustable needle valve. Once the lift rises to a high positoin, but the power provide is reduce, the decreasing movement is managed by the manual override perform.
Energy UNITS FOR LIFT TABLE three
Standard Description
This electrical power unit is built solely to the massive lift table, Consisting of hugely effecient gear pump, AC motor, multi-functional manifold, valves, tank, ect. The lowering motion is actived from the solenoid valve plus the velocity managed by a strain compensated flow management valve.
Energy UNITS FOR LIFT TABLE 4
Standard Description
This electrical power unit is developed solely for that large lift table, Consisting of extremely effecient gear pump, AC motor, multi-functional manifold, valves, tank, ect. The decreasing motion is actived through the solenoid valve as well as the velocity controlled from the adjustable needle valve. Once the lift rises to a large positoin, but the electrical power provide is lower, the lowering motion is managed through the manual override function.
Specific Notes
one. This energy unit is of S3 duty cycle, which might only perform intermittently and repeatedly, i.e. one minute on and 9 minutes off.
two. Clean all the hydraulic elements concerned just before set up of the electrical power unit.
three. Viscosity from the oil shoud be 15~46 cst,which need to also be clean and no cost of impurities.N46 hydraulic oil is advised.
four. Oil shifting is required after the initial 100 operation hours,afterwards as soon as just about every 3000 hrs.
five. The energy unit proven is intended to be mounted vertically.